Aerial Bundled Cable

  • Conductor:

    Aerial Bundled Cable(ABC) Stranded Aluminum Conductor of Class 1/2 (Solid)

  • Insulation:

    PVC/PE/XLPE Compound

  • Insulation Color:

    Black

  • Temperature Range:

    -30 - 70℃

  • Nominal Voltage:

    600/1000V

  • Test Voltage:

    3500 V

  • Standard:

    IEC 60552

Description Aerial Bundled Cable(ABC)
Conductor: Stranded Aluminum Conductor of Class 1/2 (Solid)
Insulation: PVC/PE/XLPE Compound
Insulation Color Black
Temperature Range: -30 - 70℃
Nominal Voltage: 600/1000V
Test Voltage: 3500 V
Minimal Bending Radius: 12D
Standard IEC 60552
Nominal cross-section area  Conductor structure Insulation material Insulation Thickness  Approx. Overall Diameter  Approx.
weight 
Phase 
(Compacted AL)
Neutral
(bare ACSR)
(mm2) (No./mm) Aluminum (No./mm) Steel (No./mm) (mm) (mm) (kg/km)
1x16+16 7/1.72 6/1.72 1/1.72 PVC/PE/XLPE  1.2 12.5 121.9
1x25+25 7/2.15 6/2.15 1/2.15 PVC/PE/XLPE 1.2 14.9 182.2
1x35+35 7/2.54 6/2.54 1/2.54 PVC/PE/XLPE 1.4 17.5 254.7
1x70+70 19/2.15 12/2.15 7/2.15 PVC/PE/XLPE 1.4 23.6 382.2
1x95+95 19/2.54 12/2.54 7/2.54 PVC/PE/XLPE 1.6 27.6 528.2
2x16+16 7/1.72 6/1.72 1/1.72 PVC/PE/XLPE 1.2 14.2 187.6
2x25+25 7/2.15 6/2.15 1/2.15 PVC/PE/XLPE 1.2 16.7 273.8
2x35+35 7/2.54 6/2.54 1/2.54 PVC/PE/XLPE 1.4 19.7 386.9
2x70+70 19/2.15 12/2.15 7/2.15 PVC/PE/XLPE  1.4 26.1 617.2
2x95+95 19/2.54 12/2.54 7/2.54 PVC/PE/XLPE  1.6 30.5 850.9
3x70+70 19/2.15 12/2.15 7/2.15 PVC/PE/XLPE  1.4 29.7 1024.3
3x95+95 19/2.54 12/2.54 7/2.54 PVC/PE/XLPE 1.6 34.6  

Spec Conductor structure Insulation Insulation
Thickness
Approx Overall Diameter Approx weight
Phase
(AL)
Neutral
(AL)
mm2 No./mm No./mm (mm) (mm) (kg/km)
1*10+1*10 7/1.35 7/1.35 PVC/PE/XLPE  1 10.1 71.5
1*16+1*16 7/1.72 7/1.72 PVC/PE/XLPE 1.2 12.5 110.1
1*25+1*25 7/2.15 7/2.15 PVC/PE/XLPE 1.2 14.9 163.9
1*35+1*35 7/2.54 7/2.54 PVC/PE/XLPE 1.4 17.5 229
1*50+1*50 7/2.92 7/2.92 PVC/PE/XLPE 1.4 20.1 300
1*70+1*70 19/2.15 19/2.15 PVC/PE/XLPE 1.4 23.6 423.2
1*95+1*95 19/2.54 19/2.54 PVC/PE/XLPE 1.6 27.6 585.4
2*16+1*16 7/1.72 7/1.72 PVC/PE/XLPE 1.2 14.2 175.8
2*25+1*25 7/2.15 7/2.15 PVC/PE/XLPE  1.2 16.7 258.4
2*35+1*35 7/2.54 7/2.54 PVC/PE/XLPE  1.4 19.7 361.2
2*50+1*50 7/2.92 7/2.92 PVC/PE/XLPE  1.4 22.5 472.1
2*70+1*70 19/2.15 19/2.15 PVC/PE/XLPE  1.4 26.1 658.3
2*95+1*95 19/2.54 19/2.54 PVC/PE/XLPE 1.6 30.5 908.2
3*16+1*16 7/1.72 7/1.72 PVC/PE/XLPE 1.2 16.3 241.5
3*25+1*25 7/2.15 7/2.15 PVC/PE/XLPE 1.2 19.1 353.6
3*35+1*35 7/2.54 7/2.54 PVC/PE/XLPE 1.4 22.5 493.5
3*50+1*50 7/2.92 7/2.92 PVC/PE/XLPE 1.4 25.7 644.1
3*70+1*70 19/2.15 19/2.15 PVC/PE/XLPE 1.4 29.7 895.2
3*95+1*95 19/2.54 19/2.54 PVC/PE/XLPE 1.6 34.6 1233