Russian Spanish

Email: [email protected]

Site Map
  • home
  • products
    • Building Wire

      PVC Insulated Aluminum Cable

      Flexible Flat Cable

      Single Core Flexible Cable

      Twin and Earth Cable

      Aluminum Flat Cable

      Single Core PVC Insulated Cable

    • PVC Insulated Wire

      Concentric cable

      Twisted Flexible Cable

      Audio Speaker Cable

      Single Core PVC Insulated Cable

      Aluminum PVC Insulated Cable

    • Power Cable

      600-1000V AL PVC/XLPE Power Cable

      600 1000V CU XLPE Power Cable

      600-1000V Flexible Power Cable

      600/1000V SWA Armoured Cable

      600-1000V PVC Insulated Cable

      600-1000V STA Armoured Cable

    • Multicore PVC Cable

      SOCAPEX CABLE

      Multicore Flexible Cable

      Multicore High Flexible Cable

      Multicore Solid Cable

      Flexible Unshielded Cable

    • Control Cable

      EV Charging Cable

      TUV Solar cable

      Instrument cable

      Transparent Shielding Control Cable

      Transparent Audio Cable

      Solid Unshielded Control Cable

      Flexible Shielded Control Cable

    • Aerial Cable

      AAC - All Aluminum Conductor

      ACSR Conductor

      Aerial Bundled Cable(ABC cable)

    • Rubber Cable

      Flat Elevator Cable

      Silicone Wire

      Submersible Pump Cable

      Rubber Sheathed Cable

      Welding Cable

    • Cable Accessories

      Cable lugs

      Cable Trays

      Aluminum-Disk

      Enameled Wire

      Aluminum Rope

      Copper Rope

  • about us

    Company Profile

    Production Lines

    Quality Control

    Certification

  • news & exhibition

    Company news

    Industry News

    Exhibition

    Case

  • Agency

    Agents

    Agency Clause

  • service

    Trading Process

    Technical Support

    FAQ

    Company Video

  • contact us

Your position: Home > news & exhibition > Industry News

Company news Industry News Exhibition Case
  • Cable number of cores

    Cable rated voltage and the relationship between the number of cores

    In the choice of cable, you need to consider the cable voltage and cable core number of these two factors, but many people do not understand, here to give you a detailed description of the cable rated voltage and cable core what is the relationship between.

    Jan 08,2018
  •  power cable

    6 kinds of commonly used power cable characteristics

    Power cable models are more different models also have different characteristics and suitable occasions, so we still have to understand the characteristics of different power cables, so as to find their own power cable models, here to give you a brief introduction to 6 Common power cable features:

    Jan 06,2018
  • Wire and cable insulation

    Wire and cable insulation material selection

    PVC plastic is based on polyvinyl chloride resin, adding a variety of complexing agent mixture. Its excellent mechanical properties, chemical resistance, no fire, weather resistance, good electrical insulation properties, easy processing, low cost, it is a good material for wire and cable insulation and sheathing.

    Jan 05,2018
  • Wire and cable

    Wire and Cable 8 major production processes

    Wire and cable are based on the length of the basic unit of measurement. All wire and cable from the beginning of conductor processing, the conductor's outer layer with insulation, shielding, cable, sheath, etc. made of wire and cable products. The more complex the product structure, the more the level of the overlay.

    Jan 04,2018
  •  wires and cables

    How to distinguish between wires and cables

    The difference between a wire and a cable is that the size of the wire is generally small. The larger conductor cross-sectional area (larger than 6 mm2) is called a large wire and a cable, and the smaller (6 mm2 or less) is called a small wire. An insulated wire is Also known as cloth wire. However, cables are sometimes classified as cables in a broad sense.

    Jan 03,2018
  • wire and cable shielding

    Why use wire and cable shielding

    Shielded cable is the use of metal mesh braid layer to wrap the signal transmission line. Braid is generally copper or tinned copper. Shielding is to ensure the transmission performance of the system under electromagnetic interference. The anti-interference here should include two aspects, that is, the ability to resist external electromagnetic interference and the system itself to radiate electromagnetic interference.

    Jan 02,2018
  • Wire and cable manufacturing process

    Wire and cable manufacturing process

    Wire and cable manufacturing involves a wide range of processes, from non-ferrous metal smelting and pressure processing, to plastics, rubber, paint and other chemical technology; fiber materials around the package, weaving and other textile technology, metal materials to the package and the metal strip Longitudinal package, welding metal forming process. Equipment involved, such as extrusion machine series, drawing machine series, stranding machine series, around the charter series.

    Dec 28,2017
  • armoured cables

    The difference between armored cable and ordinary cable

    Armoured cables are made of different material conductors in metal sleeves with insulating materials and are processed into a solid, flexible combination. Armored cables include armored thermocouples, armored thermal resistors, armored heaters and armored leads. They are mainly used for temperature measurement, signal transmission and special heating for the chemical, metallurgy, machinery manufacturing, power generation and scientific test. The largest amount is the armored thermocouple.

    Dec 27,2017
  • 0.6/1kv PVC insulated power cable

    0.6/1kv PVC insulated power cable

    0.6/1kv PVC insulated power cable is suitable for transmission lines with rated voltage 0.6/1kv, which can be used for transmission and distribution. PVC plastic cheap, good physical and mechanical properties, simple process, but the insulation performance in general. As a result, a large number of low voltage power cables are used to produce low voltage power cables for 1 thousand volts and below, for low voltage distribution systems.

    Dec 26,2017
  • cable and wire

    Classification of wire and cable

    The classification of wire and cable products can help you better understand the specifications and models. The main types of wire and cable are as follows:bare copper wire,power cable,overhead insulated cables,control cable,special cable.

    Dec 25,2017
  • power cable and control cable

    What is the difference between power cable and control cable

    The Power cable is a cable product that is used to transmit and distribute high power energy in main lines of the power system, including 1-500KV and above all kinds of voltage levels, all kinds of insulated power cables.Control cable insulation wire color is generally black and white printing, low voltage power cable is usually color. Generally, the section of the control cable will not exceed 10 square. The electric power cable is mainly the transmission of the electric power, which is generally large section.

    Dec 23,2017
  • XLPE insulated cables

    XLPE insulated cables

    XLPE insulated cable is a suitable distribution network and other areas of the cable, PVC insulated cables with unparalleled advantages. Its simple structure, light weight, good heat resistance, load capacity, not melting, chemical resistance, high mechanical strength.

    Dec 21,2017
  • wire and cable products

    What are the structural components of wire and cable products?

    The structural elements of wire and cable products can be divided into four major structural components of wire, insulation, shielding, and sheath as well as filling elements and tensile elements. Wires and insulation are the two basic components that must be available to make a cable product (except for bare wires).

    Dec 20,2017
  • cable and wire

    How much can 1, 1.5, 2.5, 4, 6 square wires load kW?

    When buying electric wires, Many people will ask about a load of wires with the different cross-sectional area. There are 1 square wires, 1.5 square wires, 2.5 square wires, 4 square wires, 6 square wires and so on. The following is to give you a brief introduction of how many watts can be loaded by these wires.

    Dec 19,2017
  •  PVC and XLPE

    What is the difference between PVC and XLPE

    The structural elements of wire and cable products can be generally divided into four main structural components of wire, insulation, shielding, and sheathing. For power cables, according to different insulating materials, low-voltage power cables are mainly the following two kinds: PVC insulated power cables and XLPE insulated power cables.

    Dec 18,2017
  • electrical cable

    How to determine whether copper is real

    How to determine whether copper is real--how to indicate pure copper electrical wireDue to copper's conductivity, the metal is used frequently as electrical wir...

    Mar 30,2017
  • power cable wire

    THE CABLE RESISTANCE CALCULATION METHOD

    THE CABLE RESISTANCE CALCULATION METHODConsider an example using the reistance formula:-A copper conductor of length 500 meters is used to supply electrical en...

    Mar 20,2017
  • power cable wire

    How to Size the Neutral Conductor in an Electrical Installation

    In a balanced three phase systems, the current in the neutral conductor is theoretically zero. However in a practical electrical installation, this is not the c...

    Mar 13,2017
  • cable and wire

    Basics of Transformer Ratings

    Basics of Transformer RatingsTransformers are rated using several methods. Two common ratings of transformers include the:(1) KVA rating(2) Impedance ratingKV...

    Mar 03,2017
  • Cable Wires

    Uses of Different Types of Cable Wires

    Cable wires have become very important for us and without them we would end up having no power. These wires are used to carry electrical current to our homes, offices, industries etc... the most important use so far of these cable wires. These wires are installed in houses, buildings etc... taken underground to everywhere and anywhere where there is human population and electricity is needed.

    Dec 17,2016
  • electrical cable

    Wiring safety codes for electrical cable

    Wiring safety codes are intended to protect people and property from electrical shock and fire hazards. Regulations may be established by city, county, provincial/state or national legislation, usually by adopting a model code (with or without local amendments) produced by a technical standards-setting organisation, or by a national standard electrical code.

    Dec 17,2016
  • Color Code of Electrical Cable

    Color Code of Electrical Cable

    Color Code: To enable wires to be easily and safely identified, all common wiring safety codes mandate a colour scheme for the insulation on power conductors. I...

    Oct 19,2016
  •  Cable and Wires

    Specifications and types of Cable and Wires

    Cable is usually composed of several conducted lines or several groups, between which there are the insulation material and be got into a clinch. Meanwhile, over the whole item is the high quality insulation to be the protected cover. The cable is usually adopted in the high or amounted in the earth or water to transmit the telecommunications or electricity. In 1832, Baron Schilling, a Russian army officer, invested the cable that he bore the telecommunication cable in the earth, which put six conducted lines into a glass bar, the first underground cable.

    Oct 17,2016
 48   Home Previous 1 2

Looking for foreign agency

Contact us

Products list

  • Building Wire
  • PVC Insulated Wire
  • Power Cable
  • Multicore PVC Cable
  • Control Cable
  • Aerial Cable
  • Rubber Cable
  • Cable Accessories

Contact us

  • Office Tel: +86-0371-53395807

  • Factory Tel: +86-18135696936

  • Whatsapp/Wechat: 15136241082

  • Email:[email protected]

  • Add: Zhitian Industrial Area, Gongyi City, Henan Province, China.

Follow us :

Inquiry

Copyright © 2014 Henan Sanheng Industrial Co., Ltd. All Rights Reserved. Site Map

Technical Support: coverweb